ECG for FL and CFL, dimmable DALI

QUICKTRONIC INTELLIGENT DALI DIM T5
Areas of application
  • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
  • Installation in emergency lighting systems according to IEC 61347-2-3, appendix J
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Sports halls and factories
  • Strip lighting
  • Shop lighting
  • Suitable for luminaires of protection class I

QUICKTRONIC INTELLIGENT DALI DIM T5

Product family features
  • Corridor function for direct connection of ECG to common motion sensor
  • Corridor function with pre-programmed light program
  • Touch DIM function for free parameterization of light value and turn on time
  • Fit for SMART GRID for feedback of consumed mains power and lamp operating hours
  • Fit for emergency function for automatic detection of emergency lighting by ECG
  • Very low standby power consumption: < 0.5 W
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Very high number of switching cycles: up to 300,000
  • Dimming range: 1…100 % (3…100 % with compact fluorescent lamp)
  • POWER2LAMP function for optimal matching of ECG power to lamp during lamp lifetime
  • Line frequency: 0 Hz, 50…60 Hz, rectified AC

Reduce Read more
QUICKTRONIC INTELLIGENT DALI DIM T8
Areas of application
  • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
  • Installation in emergency lighting systems according to IEC 61347-2-3, appendix J
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Sports halls and factories
  • Strip lighting
  • Suitable for luminaires of protection class I

QUICKTRONIC INTELLIGENT DALI DIM T8

Product family features
  • Corridor function for direct connection of ECG to common motion sensor
  • Corridor function with pre-programmed light program
  • Touch DIM function for free parameterization of light value and turn on time
  • Fit for SMART GRID for feedback of consumed mains power and lamp operating hours
  • Fit for emergency function for automatic detection of emergency lighting by ECG
  • Very low standby power consumption: < 0.5 W
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Very high number of switching cycles: up to 300,000
  • Dimming range: 1…100 % (3…100 % with compact fluorescent lamp)
  • POWER2LAMP function for optimal matching of ECG power to lamp during lamp lifetime
  • Line frequency: 0 Hz, 50…60 Hz, rectified AC

Reduce Read more
DALI magic
Areas of application
  • Configuration of DALI ECG functions
  • Monitoring of DALI installations

DALI magic

Product family features
  • USB DALI converter for Tuner4TRONIC and DALI wizard software for Windows PC
  • Pushbutton to test DALI dimming without need of connection to computer
  • Powered by USB or by included universal power supply
  • Integrated automatic DALI supply of up to 64 devices (up to 4 if powered by USB)

Reduce Read more