QTz5 2X14
Product family benefits
- Compact housing
- Automatic restart after lamp replacement
Areas of application
- Public buildings
- Sports halls
- Strip lighting
- Suitable for luminaires of protection class I
Technical Data
Electrical data
Nominal voltage
220 240 V
Mains frequency
50/60 Hz
Maximum output power
2 x 14 W
Efficiency in full-load
88 %
Operating frequency
30 45 kHz
Dimensions & weight
Length
275.0 mm
Width
33.0 mm
Height
21.0 mm
Mounting hole spacing, length
265.0 mm
Product weight
120.00 g
Temperatures & operating conditions
Ambient temperature range
0 +50 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
30000 h
ECG ambient temperature (ta) |
40 °C |
50 °C |
---|---|---|
Temperature at the measuring point tc (°C) |
70 °C |
75 °C |
ECG lifespan (h) |
50000 h |
30000 h |
Capabilities
End of lamp life safety shutdown
EOL T.1
Suitable for fixtures with prot. class
I
Dimmable
No
Intended for no-load operation
No
Certificates & standards
Approval marks approval
CE / CQC
EEI Energy Label
A2
Type of protection
IP20
Protection class
I
Logistical data
Commodity code
850410809000
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
14-04-2022
Primary Article Identifier
4052899019164
Declaration No. in SCIP database
In work
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4052899019164 |
UNV
| 1 | |||
4052899019171 |
VS
| 20 | 290mm x 171mm x 160mm | 2782.00g | 7.93dm³ |
Downloads
Information about Family
Product family features
- Supply voltage: 220 240 V
- Line voltage: 198 264 V
- Line frequency: 50 Hz | 60 Hz
- Energy Efficiency Index EEI: A2
- Automatic shutdown of defective lamps and at end of life (EoL)
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.